Service Engineers Inspection 60 Points CHECKLIST

Buying a used generator need not be a gamble.

We have years of experience in diesel generators. We are committed to providing only the highest quality used diesel generators, which is why all of the used generators we sell undergo a 60 point service inspection check and a full load test prior to dispatch.

With new stock arriving each week please contact us should you not be able to find the second-hand generator you are looking for.  We also offer a wide range of new diesel generators from globally renowned brands such as Perkins, Cummins and Doosan.

How can we be confident that the diesel generator you purchase from Eurotrade-Gen is the best quality second-hand generator that you can buy?

Below is a summary of some of the key areas we test and inspect:

Engine:

  • Shutdowns tested at least 3 times during our test process.
  • Physical connections to the base frame, radiator and alternator inspected.
  • Charge alternator tested.
  • Fuel pump inspected, fuel solenoid checked, fuel linkages lubricated.
  • Fuel hoses inspected.
  • Filters changed as required and air filter assembly checked.
  • Oil tested and changed as required.
  • Low oil pressure and engine temperature.
  • Fan belts inspected, recorded and changed as necessary.

Radiator:

  • All hoses checked.
  • Fan blades and radiator fins checked.
  • Radiator checked for fin blockage and cleaned as required.
  • Coolant tested and changed as required.
  • Fan guards checked and rectified.
  • Radiator cap checked operationally.

Alternator:

  • AVR checked and tested.
  • Physical connections to the engine and base frame tested.
  • Internal inspection of slip rings and diodes completed as required.
  • Megger test if required.

Control Panel:

  • Display checked.
  • Warning lights and instrumentation checked.
  • Fuses, relays and cables inspected.
  • Panel settings for autostart and any timers recorded.
  • Auxiliary inputs recorded.

Miscellaneous:

  • Circuit breaker checked for correct operation.
  • Batteries checked and changed as required.
  • Battery charger and jacket water checked if applicable.
  • Exhaust system checked.
  • Exhaust condensate checked and drained.

Load Test:

  • All generators tested at 25%, 50%, 75% & 100% of rated load.
  • 50% load acceptance/load rejection tests completed and recorded.
  • Voltage and Frequency variation on load recorded.
  • Voltage and Frequency stability on load recorded.